Daikin Controller Quick Start Guide

. Buyer's Guide All you need to know to choose the best Air Conditioning solution for your home, all year-round.

  1. Daikin Wireless Controller
  2. Daikin Controller Manual
  3. Daikin Wired Controller

My Daikin Daikin guarantees your comfort in every facet of our service, right through from research and development to installation and enjoyment. About Us As one of Australia’s most trusted names in air conditioning, Daikin can be found in homes, businesses, and community projects across Australia.

Quick

. DDC Controller Quick Start Guide.

Part 1: Initial Computer and PrismD Setup.1 Part 2: Controller Con iguration.5 Part 3: Schedules.8 Section 2: DDC Controller Quick Start Guide (Using LCD Display). 10 Part 1: Controller Setup Using On-Board LCD Display. 10 Appendix: Optional Sensor Descriptions. 14 Troubleshooting. Section 1: Goodman DDC Controller Quick Start Guide (Using Computer) Note: This Quick Start Guide is only for reference to make the startup process faster. If more information is required on any of the features or wiring, please refer to the DDC Controller Technical Guide and the PrismD Technical Guide. Part 1: Initial Computer and PrismD Setup 1.

PrismD and the USB drivers can be downloaded at www.daikin.wattmaster.com. After PrismD and the USB drivers have been successfully installed on your computer, you can then connect a standard USB cable between the computer and controller. DDC Controller USB Cable Connect to Computer with PrismD Software Installed For Stand-Alone Programming Figure 1: USB Cable Connection 1. Note: If you are using an external CommLink 5, remove the jumpers. Cycle power to the controller if making jumper changes. DDC Controller ALARM MENU ENTER Both Jumpers ON (Default) www.wattmaster.com DOWN RS-485 COMM USE ON-BOARD 'R' LOOP WIRE 'T' “R” TO “R”,“T” TO “T” 'SH COMMLINK “SHLD” TO “SHLD” OE377-26B-00001 PCBCG100 BINAR RELAY CONTACT BINARY INPUTS (24V). 6. Click the  icon (see Figure 4). Once the Job Sites Window opens, create a name for your jobsite in the “Selected Location” field and press. Your new jobsite name should appear in the “Job Site Selection” window.

Note: When entering data in PrismD, you must always press the  key after each entry in order for the program to save the data. Note: The number following “COM” may be different on your computer. It should still start with “Silicon Labs CP210x USB to UART Bridge”. Figure 4: Job‐Site Icon and Job Sites Window 8. Figure 5: Communications Menu ‐ Search For Units 10.

When completed you should see one small green square as shown in Figure 6. Figure 6: Search For Units 11. Close the Search For Units Window by clicking. If you wish to save your search results, select  when prompted to do so. Part 2: Controller Configuration 1.

On the left‐hand side of the PrismD screen in the Unit Selection column, double‐click on the controller labeled “Daikin RTU”. Daikin RTU Figure 7: Unit Selection 2. Daikin RTU Figure 8: Controller Status Screen 5. At the top of the Status Screen next to Daikin RTU, you will see a blank time of 00.00 AM. Click on this time field to broadcast the real time to the Controller. Daikin RTU Figure 9: Broadcast Time 4.

From here, you can view the current status of the unit as well as access the settings by clicking the menu option  located at the top of the window. See Figure 10. Daikin RTU Figure 10: Setpoints Selection 6. As shown below in Figure 11, you can select the setpoint category by clicking on one of the buttons at the bottom of the screen.

Click on the  category. Note: When entering data in PrismD, you must always press the  key after each entry in order for the program to save the data. Figure 11: Controller Setpoints Screen and Setpoint Categories 6. In the Configuration Screen, there are 5 Sensor settings identified by the red arrows that are field options and they need to be set correctly in order for the controller to operate. These options are shown with arrows in Figure 12. However, you should still verify the other settings even though they should be set correctly at the factory.

Figure 12: Configuration Screen 7. Part 3: Schedules 1. The internal schedule can be changed by clicking on the  icon located on the Controller Status Screen as shown in Figure 13. Figure 13: Schedules Icon 2. Figure 14: Schedules Window 3.

When you enter a time in any field, you must type in 3 or 4 characters for each field and you must designate AM or PM and press. For example, 500 PMor 1100 PM,. Note: You MUST press  to have the system accept your entry. If you do not press, the bar graph to the right will either not display or will not change. To eliminate a schedule from any event, simply type a zero and press  for the Start and Stop time for that day. The screen will display 12:00 AM for both the Start and Stop times, indicating that the equipment will not activate for that day. If you want the controller to run the full 24 hours, type a zero and press  to set 12:00 AM for the Start time and type 11:59 PM and press  for the Stop time. This ensures the full 24‐hour period will remain in the occupied mode without interruption. Select  to save your schedule. Select  to restore a previously saved schedule. Select  to copy the schedule to all like controllers, and select  to completely erase the schedule appearing in the window. Select the  button at the bottom left of the Schedules Window to schedule Holidays. The Holidays Window will appear (see Figure 15). Click on each date you wish to select as a Holiday. All Holidays will follow the daily Holiday schedule that is set in the Schedules Window. The holiday start and stop times will override the standard operating hours.

Figure 15: Holidays Window 9. Section 2: Goodman DDC Controller Quick Start Guide (Using LCD Display) Note: This Quick Start Guide is only for reference to make the startup process faster. If more information is required on any of the features or wiring, please refer to the DDC Controller Technical Guide and the PrismD Technical Guide. Part 1: Controller Setup Using On‐Board LCD Display 1. The first LCD screen is the initialization screen.

To scroll through the rest of the screens, press the button. Press the  button until you get to the TIMER / DELAYS Screen. Then press the  button to scroll through the TIMER / DELAYS Screens. Follow the directions in Step 1. Then press the  button until you get to the CONFIG SETPTS Screen. Then press the  button to scroll through the Configuration Setpoints Screens. Follow the directions in Step 3. There are 5 Timer settings that are field options and they need to be set correctly in order for the controller to operate properly. They are shown below: 11. There are 7 Configuration settings that are field options and they need to be set correctly in order for the controller to operate properly. However, you should still verify the accuracy of all other configuration settings even though they should be set correctly at the factory. The Configuration Settings that need to be set correctly are as follows: a. Space Sensor Installed: Analog or Digital b.

Free online transmission repair manuals. AUTOMATIC TRANSMISSION SERVICE GROUP. (b) Push the manual lever fully toward the right side of. A130L, A131L 25 20 50 20.

Humidity Space Sensor Installed or Not Installed c. Humidity Space Sensor Installed: Analog or Digital d. Economizer: Economizer Only, CO or None e. Economizer Enable Source: Drybulb, Dewpoint, or Enthalpy f.

CO Sensor Installed or Not Installed g. CO Sensor Installed: Analog or Digital Use the  and  buttons to change screen values.

Daikin Wireless Controller

Appendix: Optional Sensor Descriptions If the optional sensors are purchased from Daikin, the following pictures will help you determine the type of sensor that you have. However, some of the optional sensor types are not provided by Daikin, such as the Analog Space Humidity Sensor (not shown). Analog Space Sensor Digital Space Sensor Digital Space Sensor with LCD Display without LCD Display Analog CO Sensor Digital CO Sensor 14. Troubleshooting What Can I Do If I Cannot Find Silicon Labs Under Serial Ports In PrismD? This will open your computer’s Device Manager Window. Under Ports (COM & LPT), look for Silicon Labs and verify the COM number it is installed on. With this information, go back to PrismD and under JobSite, select the correct Serial Port. In this example, COM3. Troubleshooting What If I Forget My Password?

Daikin Controller Manual

If you have changed the administrator access username and password from its default username “admin” and password “admin” and you forgot one or both, you may reset the administrator access to factory default mode by following the steps below. Under the C: drive, find and open your PrismD folder. In this folder you will find an internal folder named, “Configuration.” Double‐click to open the folder.

Inside this folder you will find multiple files. Look for a file named “ULData.cfg.” Right click on this file and select. This will reset the Username and Password to “admin” 16. WattMaster Form: DK-QS-DDC-TGD-01A June 2016 All rights reserved. Printed in the USA © 2016 WattMaster Controls Inc. 8500 NW River Park Drive.

Daikin Wired Controller

Parkville, MO. 64152.