Karcher Hds 1295 Manual

Drawing in water from tank When you suction water out of an open container you should – disconnect the water inlet at the pump head. – unscrew the top supply hose to the water tank and connect it to the pump head. – use a water suction hose with a minimum diameter of 3/4' provided with a vacuum filter. Until the pump sucks up water you should: – turn the pressure and flow regulation to MAX. – close the metering valve for the cleaning agent.

– Never suction up water out of a potable water tank. – Never suction up solvent-bearingliquids such as paint thinner, benzine, oil or unfiltered water. The seals in the unit are not resistant to solvents.

The mist of solvents is highly inflammable, explosive and poisonous! Mains connection Refer to technical data and rating plate for connected loads.

Whenever socket is changed, check direction of rotation of motor If direction of rotation is correct, powerful jet of air will be felt at exhaust-gasopening of burner. If the direction of rotation is wrong: Change the poles at the unit plug. See figure 16. If an extension cable is used, this should always be fully uncoiled and have an adequate crosssection. OPERATION Switch the unit on Set the unit switch (item 23) to 'I' The ready for working indicator lamp (item 29) is lit The temperature regulator (item 24) must be at setting '0', since it is otherwise possible that the burner switches itself on. Unit starts up briefly and is switched off as soon as operating pressure is reached.

Turn the unit off immedediately if during its operation the indicator lamps (item 25-item28) light up. Eliminate fault, refer to Faults. Figure 8 Release handgun Actuation of handgun switches unit back on again. Bleed pump if no water emerges from highpressure nozzle. Refer to Faults 'No build-upof pressure by unit' Setting cleaning temperature Set the temperature regulator (item 24) to the required temperature 30°C to 90°C Hot water cleaning 100°C to 150°C Clean with steam, with steam nozzle - 4.766-023,at HDS 1195 and HDS 1295 - 4.766-024 Setting operating pressure and flow rate Figure 9 Turning regulator clockwise: Increases operating pressure (MAX) Turning counter-clockwise:Reduces operating pressure (MIN) Servopress control Set the temperature regulator (item 24) to max. Set regulator to maximum operating pressure. Figure 8 Operating pressure and flow rate can be set at handgun.

Set pressure on unit if use is to be made of reduced pressure for a lengthy period. See figure 9. Measuring out the cleaning agent. Use cleaning agents sparingly to protect the environment. The cleaning agent must be suitable for the surface to be cleaned. Set the concentration of the cleaning agent according to the manufacturer's recommendations at the cleaning agent metering valve (item 31) Approximate values at maximum operating pressure Intended use Cleaning of: Machines, vehicles, buildings, tools, facades, terraces, garden tools, etc.

Engine cleaning is only to be performed in areas provided with oil separator. Heed appropriate safety regulations for use at petrol stations or in other hazardous environments. Working with high-pressurenozzle Spray angle is crucial to efficiency of highpressure jet. Use is normally made of 25°fan jet nozzle (included). Recommended nozzles, available as accessories – For stubborn dirt 0°full jet nozzle – For delicate surfaces and slight contamination 40°fan jet nozzle – For thick layers of stubborn dirt dirt blaster – Nozzle with variable spray angle, for adaptation to various cleaning tasks variableangle nozzle Cleaning.

Set pressure/temperature and cleaning-agentconcentration in line with surface to be cleaned. Always start by directing high-pressurejet from a good distance at object to be cleaned to avoid damage caused by excessive pressure. Recommended cleaning method Loosen up dirt: Spray on cleaning agent sparingly and allow to react for 1.5 min (do not allow to dry on). Remove dirt: Spray off loosened-updirt with high-pressurejet. Operation with cold water Removal of slight contamination and rinsing e.g.: Garden implements, terrace, tools, etc.

Set operating pressure as required Set the temperature regulator (item 24) to '0' Operation with hot water. Danger of scalding Set the temperature regulator (item 24) to the required temperature We recommend the following cleaning temperatures – Slight contamination 30-50°C – Protein soiling, e.g. In foodstuffs industry max. 60°C – Motor vehicle cleaning, machine cleaning 60-90°C Operation with steam At operating temperatures above 98°C operating pressure must not exceed 32 bar. Therefore the standard high-pressurenozzle must be replaced by the steam nozzle (manufacture no.: 4.766-023,for HDS 1195 and HDS 1295 4.766-024.0;see accessories). – Set operating pressure to minimum value. See figure 9 – Set the temperature regulator (item 24) to min.

100°C. Danger of scalding!

We recommend the following cleaning temperatures – Preservative removal, extremely greasy dirt 100-110°C – Thawing of aggregates, certain facade cleaning operations up to 140°C. Safety shut-off The pump automatically shuts down for safety reasons if the handgun is neither opened or closed for more than 30 minutes. – To switch it on again turn the main switch to '0' and then back to the 'I' position. (The EPROM without disabling 6.682-595.0is available from service) EACH TIME AFTER USAGE Following operation with cleaning agent – Set the cleaning agent metering valve (item 31) to '0' – Set the unit switch (item 23) to 'I' – Actuate handgun and flush unit for approx. 1 min Stopping machine – Set the unit switch (item 23) to '0' – Shut off water supply – Switch the pump briefly on with the unit switch (item 23) (approx. 5 sec.) – Remove mains plug from socket ONLY with dry hands – Detach water connection – Actuate handgun to depressurise unit – Lock the hand spray gun Figure 8 – Engage spray lance in cover holder – Reel up the high-pressurehose and electric cables and attach them to fastenings. Take care not to kink high-pressurehose and cable!

Karcher Hds 1295 Manual

Frost will destroy unit if water is not drained off completely! Store unit in a frost-freelocation Take unit out of service if frost-freestorage is not possible. READING THE OPERATING HOURS (ONLY HDS 995 AND HDS 1295) When you open the storage compartment cover flap,you will notice the electronic operating hours display in the viewing window, e.g.

English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295 10 Once a month Display – Clean strainer in low water protection – Clean filter at cleaning-agentsuction hose Necessary maintenance work After 500 hours of operation, at least once a – Check the overflow valve for leaks. year – Check the high-pressurehose. – Change oil – Clean the handgun – Check the pulsation damper.

This maintenance work should be performed MAINTENANCE TASKS only by after-salesservice. The indicator lamp (item.28) Cleaning strainer in water connection motor/electronics module is lit (HDS 745, HDS 695 S, HDS 895 S, HDS 995, (only HDS 995 and HDS 1295) HDS 1195, HDS 1295, HDS Super).

This warning lamp lights up when certain Figure 10 maintenance work is necessary due to – Remove strainer accumulated operating hours. – Clean in water and re-insert. When you open the cover (item 8) of the Cleaning strainer in low water protection compartment (item 6) the electronic display is (HDS 745, HDS 695 S, HDS 895 S, HDS 995, visible in the window (item 4). HDS 1195, HDS 1295, HDS Super).

Manual

Upon completing the necessary maintenance Figure 11 work the RESET button next to the display – Unfasten union nut and detach hose must be depressed at least 7 seconds until Figure 12 the warning lamp goes out. – Take out strainer Display If necessary, screw in bolt M8 approx. 5mm to pull out strainer. – Tighten drain plug again – Slowly fill with oil as far as MAX mark Air bubbles must be able to escape Refer to technical data for oil grade and quantity to be used. FAULTS The indicator lampMOTOR/ELECTRONICS MODULE (item 28) flashes (only HDS 995 and HDS 1295). This warning lamp flashes if there is a problem.

When you open the cover (item 8) of the compartment (item 6) the electronic display is visible in the window (item 4). The warning lamp goes out when the problem has been resolved and the unit is switched on again. Display Troubleshooting – Increase the water inlet volume – Clean strainer in water connection – Clean the strainer (coarse) fitted in front of the low water protection Display Troubleshooting – Replace the reed switch for the low water protection. – Clean the low water protection. Display Troubleshooting – Eliminate the leakage in the high-pressuresystem Display Troubleshooting Motor is overloaded/overheated – Set the monitoring switch to '0' and allow the motor to cool off for at least 5 min – Have unit checked by After-SalesService if this does not remedy fault. Display Troubleshooting This error code appears only on units equipped with the – accessory kit flame monitoring system - See the assembly instructions – accessory kit flame monitoring system -. This maintenance work should be performed only by after-salesservice.

The READY FOR WORKING indicator lamp (item 28) goes out (HDS 745, HDS 695 S, HDS 895 S, HDS 1195, HDS Super) Motor overloaded/overheated – Set selector switch to '0' and allow motor to cool down for at least 5 min. – Have unit checked by After-SalesService if this does not remedy fault.

– No mains voltage (see – unit does not run -) The FUEL indicator lamp (item 25) is lit (HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super) Fuel tank empty – Fill up The READY FOR WORKING indicator lamp (item 29) goes out (HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super) Engine is overloaded – Set selector switch to '0' and allow motor to cool down for at least 5 min. – Have unit checked by After-SalesService if this does not remedy fault.

Karcher Hds 750 Manual

– No mains voltage (see – unit does not run -) SCALE INHIBITOR indicator lamp (item 26) is lit (HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super) Scale inhibitor reservoir empty; for technical reasons there is always a residual quantity in the reservoir. – Fill up Dirt on electrodes in reservoir – Clean electrodes. Unit does not run (HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super) No mains voltage – Check mains connection/power cord Unit does not build up pressure (HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super) Air in system – Bleed pump:. Set the cleaning agent metering valve (item 31) to '0'. While the handgun is open switch the unit on and off several times with the unit switch. With handgun open, open and close regulator (Figure 9).

Venting is accelerated by removing the high- pressure hose from the high-pressureconnection. – Fill up cleaning-agenttank if empty. – Check connections and lines Pressure set to MIN – Set pressure to MAX Strainer in water connection dirty – Clean strainer Insufficient water supply – Check water supply volume (refer to technical data) – Unit leaking, water dripping out at bottom (HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super) Pump leaking – 3 droplets/min are permitted. – In the event of a major leak, have unit checked by After-SalesService. Unit constantly switched on and off with handgun closed (HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super) Leak in high-pressuresystem – Check high-pressuresystem and connections for leaks Unit does not draw in cleaning agent (HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super) Operate the unit with an opened cleaning agent metering valve and a shut off water inlet until. The float tank is suctioned empty and the pressure drops to '0'. – Now reopen the water inlet.

If the pump still does not suction up cleaning agent the reasons can be as follows: Filter in cleaning-agentsuction hose dirty – Clean filter Non-returnvalve gummed up – Pull the cleaning agent hose off and detach the non-returnvalve with a blunt object, see Figure 15. Burner not ignited (HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super) Fuel tank empty – Fill up Lack of water – Check water connection, check supply lines, clean low water protection. Fuel filter dirty – Replace fuel filter. Incorrect direction of rotation. If direction of rotation is correct, powerful jet of air will be felt at exhaust-gasopening of burner.

– Check direction of rotation. If necessary change the poles at the unit plug. See figure 16. No ignition spark – Have unit checked by After-SalesService if no ignition spark is visible through inspection glass during operation. Set temperature not attained when working with hot water (HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super) Excessive operating pressure/flow rate – Reduce operating pressure/flow rate by way of regulator (Figure 9) Soot deposits on heating coil – Have After-SalesService remove soot deposits from unit If the problem cannot be resolved the unit must be checked by after sales service. WARRANTY The warranty terms and conditions issued by our responsible sales company apply in every country. Within the warranty period, any faults in the unit will be rectified free of charge provided that the problem was caused by a material defect or manufacturing error.

The warranty only applies if the dealer fills in, stamps and signs the enclosed reply card when the unit is sold and the purchaser then returns it to the appropriate local distributor. In the event of a warranty claim, please contact your dealer or the nearest authorised AfterSales Service office and produce both accessories and proof of purchase. GENERAL INSTRUCTIONS Safety features.

Limited Warranty --- (USA Only) The limited warranty set forth below is given by Canon U.S.A., Inc. Protect against unforeseen repair costs, excessive downtime, and enjoy peace of mind for years to come knowing your new equipment is fully covered.* Not available in the state of Wyoming or New Mexico. Limited Warranty & InstantExchange Program Details Canon U.S.A., Inc. Pixma mg3220 manual. ('8220;Canon USA') with respect to the new or refurbished Canon-brand product ('Product') packaged with this limited warranty, when purchased and used in the United States only.

Overflow valve with two pressure switches When reducing water volume at pump head or with the servopress control, the overflow valve will open and part of the water will flow back to the pump suction side. If the handgun is closed thus causing all the water to return to the pump suction end, the pressure switch at the overflow valve shuts off the pump.

Reopening the handgun causes the pressure switch at the cylinder head to switch the pump back on again. The overflow valve is set at the factory and lead-sealed.Adjustment can only be made by After-SalesService.

Safety valve The safety valve opens if the overflow valve or pressure switch is defective. The safety valve is set at the factory and sealed. Adjustment can only be made by After-SalesService. Low water protection The low water protection stops the burner being switched on in the event of a lack of water. A strainer stops the protection feature becoming dirty and requires regular cleaning. Motor protection switch The motor protection switch interrupts the circuit should overloading occur. Guidelines for liquid spraying equipment.

The accident prevention directive (BGV D 15) Work with Jets of Liquids is applicable. In accordance with these guidelines, highpressure spraying equipment must be checked at least every 12 months by an expert and the results of the inspection recorded in writing. Order governing boilers. The testing pressure and the design of the unit comply with the steam boiler directive! The water content of the heating coil is less than 10 litres. The boiler section of the unit is thus not subject to installation regulations. Local building regulations are to be heeded.

Switching on procedures. Switching on procedures generate brief voltage drops. Impairments of other appliances can occur in cases of unfavourable mains conditions. No problems are to be expected with a mains impedance of less than 0,15 ohm. English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295 14 TECHNICAL DATA Type HDS Super (1.025) HDS 695 S.

AUS (1.025-305) HDS 745 (1.026) HDS 895 S (1.027) Mains connection 420 V 420 V 240 V 110 V 420 V 3 50 Hz 3 50 Hz 1 50 Hz 1 50 Hz 3 50 Hz Connected load 6,4 kW 5,6 kW 3,2 kW 3,2 kW 6,8 kW Fuse (slow blow) 16 A 16 A 16 A 30 A 16 A Water connection Supply temperature max.30 °C max.30 °C max.30 °C max.30 °C Supply volume min. 1200 l/h min. 1000 l/h min. 1000 l/h min. Type HDS 995 (1.027) HDS 1195 (1.028) HDS 1295 (1.028) Mains connection 420 V 420 V 420 V 3 50 Hz 3 50 Hz 3 50 Hz Connected load 6,8 kW 8,2 kW 8,2 kW Fuse (slow blow) 16 A 16 A 16 A Water connection Supply temperature max.30 °C max.30 °C max.30 °C Supply volume min. 1200 l/h min.

1500 l/h min.